News

Instructions For Use Of The Hot Plate

1. When using this type of electric heating device, it must be noted that the working temperature of its continuous use should be less than 240 °C, and the instantaneous temperature should not exceed 300 °C.

2. The silicone electric heating device can work and be under pressure, that is, use an auxiliary pressure plate to make it close to the heated surface. At this time, the heat conduction is good, and the power density can reach 3W/cm2 when the temperature of the working area does not exceed 240℃.

3. Under the condition of paste type installation, the allowable working temperature is less than 150℃.

4. In the case of dry burning in the air, the power density should be less than 1W/cm2 due to the temperature resistance of the material; in non-continuous conditions, the power density can reach 1.4W/cm2.

5. The working voltage is selected based on the principle of high power-high voltage, low power-low voltage, and special needs can be excluded

6. The power supply that meets the requirements of the instrument must be used. The power socket should be a three-hole safety socket and a ground wire should be installed.

7. First of all, there will be slight smoke, which is a normal phenomenon.

8. During use, the heating medium should be prevented from overflowing the vessel and flowing into the box to damage the electrical appliance.

9. If a fault occurs during use, the power supply should be cut off and then repaired.

10. Empty burning is prohibited.